Aveva. Pdms. Nozzle Rating and Size on face of Isometric

How to output Nozzle description on isometric.

2017-05-05_184946

There are two methods:
1 – set flange (connected to NOZZ) UDA and config option file set ‘OUTC UDA ON FLAN‘  and set ‘CONTINUATIONSYMBOLS NOZZ‘ ( to output dotted)
2 – create additional table with C# and other hardcore coding with autolisp and cmd..

Here is pmlmac file that can be used to fill UDA (in my case :MDSComment) value for all FLAN connected to NOZZ written by  aequitas.